Gas Torch Welding

CONCOA GAS MIZER GASAVER Brazing OXY Cutting Torch Saver Propane Nat. 803-0480

CONCOA GAS MIZER GASAVER Brazing OXY Cutting Torch Saver Propane Nat. 803-0480
CONCOA GAS MIZER GASAVER Brazing OXY Cutting Torch Saver Propane Nat. 803-0480
CONCOA GAS MIZER GASAVER Brazing OXY Cutting Torch Saver Propane Nat. 803-0480
CONCOA GAS MIZER GASAVER Brazing OXY Cutting Torch Saver Propane Nat. 803-0480
CONCOA GAS MIZER GASAVER Brazing OXY Cutting Torch Saver Propane Nat. 803-0480
CONCOA GAS MIZER GASAVER Brazing OXY Cutting Torch Saver Propane Nat. 803-0480
CONCOA GAS MIZER GASAVER Brazing OXY Cutting Torch Saver Propane Nat. 803-0480
CONCOA GAS MIZER GASAVER Brazing OXY Cutting Torch Saver Propane Nat. 803-0480
CONCOA GAS MIZER GASAVER Brazing OXY Cutting Torch Saver Propane Nat. 803-0480
CONCOA GAS MIZER GASAVER Brazing OXY Cutting Torch Saver Propane Nat. 803-0480
CONCOA GAS MIZER GASAVER Brazing OXY Cutting Torch Saver Propane Nat. 803-0480
CONCOA GAS MIZER GASAVER Brazing OXY Cutting Torch Saver Propane Nat. 803-0480

CONCOA GAS MIZER GASAVER Brazing OXY Cutting Torch Saver Propane Nat. 803-0480
A Gas Mizer can save you up to 50% on oxygen and fuel gas consumption in operations where torches are used intermittently. Installed between the regulator and the torch, a Gas Mizer will close off the oxygen and fuel gas supply whenever the torch is hung from the handy arm hook. When the torch is picked up, the Gas Mizer starts the flow of oxygen and fuel gas.

The torch can be ignited by passing it across the pilot light. Drilled for bench mounting, the Gas Mizer may be mounted right at the work area for maximum convenience. The inlet and outlet have B connections.

The Mizer is an accessory for inside bench production and assembly line. Gas welding and heating operations. It is designed for use in the oxygen. And fuel gas supply, low pressure line of a hand welding torch. Hand torch is hung on the Mizers hanger rod, oxygen and fuel gas are shut.

Pilot light burner tips are not included with the Mizer, but are required. Order them separately for MAPPĀ® gas, propane, acetylene.

The inlet side of the Gas Mizer is equipped with a fuel gas pilot light. Inlet and outlet nipples are B size, RH for oxygen and LH for fuel gas. Mizers shut off valves can be individually adjusted by their seat adjustment. This seat adjustment controls ignition by: LEAD for ON.

Install pressure regulators on cylinders (or pipline branch). CONCOA manual Safe Practices in Welding & Cutting, ADE 872, and. Torch and regulator instruction manuals. Secure the Gas Mizer on a bench or other horizontal surface, using.

Position the Mizer so that when the torch is. Hung on the hanger, torch tip will point away from operator and. Connect the fuel gas hose to the inlet marked FUEL GAS and the. Oxygen hose to the other inlet. Refer to the above table for hose.

Turn off pilot light adjusting valve (clockwise). Connect torch hoses to respective Mizer outlets. Screw pilot light burner (for fuel gas to be used) into Mizer needle. Valve securely so that is does not leak. Hoses for use with acetylene only - Grades R and RM.

Fuel gases (including acetylene) - Grade T. CGA G-1 5.3.3.13 To minimize the withdrawal of liquid solvent, acetylene. Should be withdrawn from the cylinder at a rate not to exceed 1/10 (onetenth). Of the capacity of the cylinder per hour during intermittent use. Full withdrawal of the contents of the cylinder on a continous basis, the flow.

Rate should be no more than 1/15 (one-fifteenth) of the capacity of the cylinder. Check valves prevent the reverse flow of mixed gases. B size 830 4199 Oxygen, 830 4200 Fuel.

Torch Check Valves B size 831. 4146 Oxygen, 831 4138 Fuel. For Maximum Safety Use Flashback Arrestors. Regulator Mounted Regulator Mounted Torch Mounted.

Model -78 Resettable Model 65 Model 460. 801 0786 B Size Oxy.

801 0536 B Size Oxy. 801 1466 B Size Oxy. 801 0789 B Size (Fuel) 801 0539 B Size (Fuel) 801 1469 B Size (Fuel). UL Listed --- Meets OSHA Requirements --- Comply with ISO 5175.

Purge lines individually, pressurize, and test for leaks at valve seats. Valve stem packings, hose connections, and pilot light connections. With an approved oxygen compatible leak detection fluid. With the torch off the hanger rod, turn the pilot light adjusting needle. Valve counterclockwise and immediately light the pilot with a sparklighter. Adjust the flame with the valve until satisfactory. Use the torch as usual but when through, instead of closing the torch. Valves, place the torch on the hanger rod to extinguish the flame. Flame away from bench as torch is hung. For reuse, remove torch from.

Hanger rod and without delay relight at pilot flame. The Gas Mizer does not affect regulator pressure settings for the torch. Use the same pressure settings at each regulator, as if this device were not. When placing the Mizer in operation, the hanger rod should be adjusted.

So that the hand torch will shut off the fuel gas and oxygen valves with its. Close the pilot valve by turning the pilot valve T-handle clockwise.

Tighten only enough to ensure a tight seal. With the torch off the hanger, adjust pressures and flames. When the torch is placed on the hanger rod, the flames should.

If the flames to do not shut off, perform the following. Loosen the hanger rod adjustment screw and slide the hanger rod. And torch to a point where the valves shut off fuel gas and oxygen. Tighten the hanger rod adjustment screw and turn off the fuel gas. Readjust, if necessary, the seat adjusting screws.

Off simultaneously, flashing or popping can be eliminated by lagging. The seat adjusting screw is nylon; care should be taken to avoid stripping.

The threads when tightening the locknuts. Shut off valves upstream of regulators. Open torch valves to bleed system before closing the regulator. This will ensure regulator is drained before repressurizing.

Shut off regulators by turning the regulator adjusting screws counterclockwise. Remove Gas Mizer from system.

Send faulty equipment to a CONCOA-designated repair center for repairs. Special tools and techniques are required to repair such equipment. Personnel with experience with such equipment should perform repairs. Shut off gas supplies at source before attempting inspection or service unless. Leak testing with an approved oxygen compatible leak detection fluid.

Servicing is usually required if gas escapes from the hand torch when it is on. The hanger rod; test by hand pressure on the hanger rod. If the torch and station outlet valves are closed, but the regulator indicates a. Slow change in pressure when the torch is off the hook, the quad-ring seal in.

The Mizer may be damaged. Damage to this seal will allow gas to escape past. This condition may also be caused by a hose connection. Test with an approved oxygen compatible detection fluid. Use only lubricants compatible with oxygen. This manual provides installation and operation information for the. The item "CONCOA GAS MIZER GASAVER Brazing OXY Cutting Torch Saver Propane Nat. 803-0480" is in sale since Thursday, November 16, 2017.

This item is in the category "Business & Industrial\Manufacturing & Metalworking\Welding & Soldering\Welding\Welders, Cutters & Torches\Gas Welding Torches". The seller is "ohiotroy" and is located in Westerville, Ohio. This item can be shipped to United States.

  • Brand: CONCOA
  • MPN: 8030480
  • Package: 1
  • Country/Region of Manufacture: United States
  • Model: GAS MIZER Gasaver Hang On Valve Gas Saver Torch


CONCOA GAS MIZER GASAVER Brazing OXY Cutting Torch Saver Propane Nat. 803-0480